| Version | Crushing resistance | Format | Diameters | Standard |
|---|---|---|---|---|
| Bars 450N | 450N | Bars 6/12 m | DN 110–200 | EN 61386-24 |
| Coils 450N | 450N | Coils 25/50/100 m | DN 40–200 | EN 61386-24 |
| Bars 750N | 750N | Bars 6/12 m | DN 110–200 | EN 61386-24 |
NTET’s PipeKorr Cable Duct range comprises rigid double-wall corrugated pipes in high-density polyethylene (HDPE), designed for laying and permanently protecting electrical, telephone and fibre-optic cables.
Produced by continuous co-extrusion of the two walls, they offer excellent mechanical properties with crushing resistances of 450 N and 750 N. Compliant with EN 61386-1 and EN 61386-24, IMQ certified and CE marked. Available in bars (6 and 12 m) and coils (25, 50, 100 m) with coupling sleeve included.
Three versions to cover every requirement for mechanical strength and packaging format.
Rigid bars version with 450 N crushing resistance. Diameters DN 110–200 mm, standard lengths 6 and 12 m. Complete with coupling sleeve. Colours: Black/Black and Grey/Yellow.
| Parameter | Value | Unit |
|---|---|---|
| Crushing resistance | 450N | |
| Certification | IMQ – CE marking | |
| DN/OD 110 → DN/ID 92 | Bars 6 / 12 m | |
| DN/OD 125 → DN/ID 105 | Bars 6 / 12 m | |
| DN/OD 160 → DN/ID 136 | Bars 6 / 12 m | |
| DN/OD 200 → DN/ID 172 | Bars 6 / 12 m |
Flexible coils version with 450 N resistance. Extended diameter range from DN 40 to DN 200 mm. Coils of 25, 50 and 100 m with pre-inserted draw wire. Wide colour range: Black, Red, Blue.
| Parameter | Value | Unit |
|---|---|---|
| Crushing resistance | 450N | |
| Pre-inserted draw wire | Yes | |
| DN/OD 40 → DN/ID 31 | Coils 25–100 m | |
| DN/OD 50 → DN/ID 40 | Coils 25–100 m | |
| DN/OD 63 → DN/ID 51 | Coils 25–100 m | |
| DN/OD 75 → DN/ID 61 | Coils 25–50 m | |
| DN/OD 90 → DN/ID 74 | Coils 25–50 m | |
| DN/OD 110 → DN/ID 92 | Coils 25–50 m | |
| DN/OD 125 → DN/ID 104 | Coils 25–50 m | |
| DN/OD 160 → DN/ID 136 | Coils 25 m | |
| DN/OD 200 → DN/ID 172 | Coils 25 m |
High-strength rigid bars version with 750 N crushing resistance. For installations with higher loads. Diameters DN 110–200 mm, bars 6 and 12 m. Colours: Black/Black and Grey/Yellow.
| Parameter | Value | Unit |
|---|---|---|
| Crushing resistance | 750N | |
| Certification | IMQ – CE marking | |
| DN/OD 110 → DN/ID 92 | Bars 6 / 12 m | |
| DN/OD 125 → DN/ID 105 | Bars 6 / 12 m | |
| DN/OD 160 → DN/ID 136 | Bars 6 / 12 m | |
| DN/OD 200 → DN/ID 172 | Bars 6 / 12 m |
| Version | Crushing resistance | Format | Diameters | Standard |
|---|---|---|---|---|
| Bars 450N | 450N | Bars 6/12 m | DN 110–200 | EN 61386-24 |
| Coils 450N | 450N | Coils 25/50/100 m | DN 40–200 | EN 61386-24 |
| Bars 750N | 750N | Bars 6/12 m | DN 110–200 | EN 61386-24 |
Download the data sheets for each version of the double-wall corrugated HDPE cable duct.
PipeKorr cable ducts are designed for the permanent protection of cables in any infrastructure context.
Mechanical protection of electrical distribution cables in urban and extra-urban burial. The 750N versions for road crossings and high-load areas.
Ducting for fibre-optic and copper cables. The 450N coils in small diameters (DN 40–63) are ideal for FTTH networks. Blue and Red colours make it easy to identify backbones.
The 750N Bars version offers the mechanical strength required for installations beneath roads, railways and airports with heavy vehicle loads.
Protection of railway, road and plant signalling cables. The coils allow continuous laying over long runs, minimising joints.
Ducts for laying the power-supply cables of urban public-lighting systems, with a coupling sleeve for quick installation.
The number indicates the crushing resistance in Newtons. The 450N version is suitable for most standard installations (trenches, pavements, green areas). The 750N is designed for areas with higher loads: road crossings, heavy-vehicle areas, greater depths.
The coils offer continuity without joints over long runs (25, 50 or 100 m), reducing laying time and costs. They are more flexible and also available in small diameters (DN 40–90) that are not available in bars. The bars (6 and 12 m) offer greater rigidity and are easier to align in the trench over straight runs.
The colours allow immediate identification of the type of protected cable: Black for general use, Red for power cables, Blue for telecommunications and fibre optics, Grey/Yellow for specific applications. This eases maintenance and reduces the risk of errors on site.
Yes, all versions (bars and coils) are supplied complete with a coupling sleeve. The coils also include a pre-inserted draw wire to ease pulling the cable inside the pipe with a pulling cord.
The cable ducts are certified by the IMQ institute, CE marked according to EN 61386-1 and EN 61386-24. Production takes place in ISO 9001 (quality) and ISO 14001 (environment) certified plants. The company is registered with the mandatory Ecopolietilene Consortium and publishes a Sustainability Report compliant with the GRI Standards 2021.
Standard bars are 6 and 12 m, coils 25, 50 and 100 m. Other sizes and lengths are available on request. Contact the sales department for specific site requirements.