Structure and materials
- Preassembled multipolar cord for MV CT/VT
- Flexible tinned copper conductors
- High-resistance PVC insulation
- Protective sheath made of self-extinguishing material
- Preinstalled GME connectors for quick connection
The N0CE0173 series connection cords connect GME electronic metering units to current and voltage transformers in medium voltage systems. Supplied preassembled, they ensure fast and safe wiring inside MV delivery compartments, with certified electrical characteristics and dedicated connectors for CTs and VTs.
Connection cord GME to MV CT/VT, Enel table DMI03101/1, Enel registration number 539003.
| Parameter | Value | Unit |
|---|---|---|
| Product codes | N0CE0173/1 – N0CE0173/2 | |
| Description | GME connection cord to MV CT/VT | |
| Available lengths | 5 m (N0CE0173/1) – 11 m (N0CE0173/2) | |
| Rated voltage | 400 V | |
| Rated insulation voltage | 500 V | |
| Impulse withstand voltage | 6 kV | |
| Rated frequency | 50 Hz | |
| Rated current | 20 A | |
| Short-time withstand current | 6 kA for 1 s | |
| Operating temperature range | da –25 °C a +60 °C | |
| Degree of protection on metering unit side | IP43 | |
| Degree of protection on CT/VT plug side | IP53 | |
| CT/VT plug material | Self-extinguishing synthetic resin class V0 (UL 94 standard) | |
| Flexible conduit | Compliant with CEI EN 61386-1 and CEI EN 61386-23 | |
| Intended use | Connection of GME MV DMI02004 to CT DMI031014 and VT DMI031015 in MV delivery compartments | |
| Installation | Indoor | |
| Product category | Connection cords for MV metering units |
Connection cord GME to MV CT/VT, Enel table DMI03101/2, Enel registration number 539005.
| Parameter | Value | Unit |
|---|---|---|
| Product codes | N0CE0173/1 – N0CE0173/2 | |
| Description | GME connection cord to MV CT/VT | |
| Available lengths | 5 m (N0CE0173/1) – 11 m (N0CE0173/2) | |
| Rated voltage | 400 V | |
| Rated insulation voltage | 500 V | |
| Impulse withstand voltage | 6 kV | |
| Rated frequency | 50 Hz | |
| Rated current | 20 A | |
| Short-time withstand current | 6 kA for 1 s | |
| Operating temperature range | from –25 °C to +60 °C | |
| Degree of protection on metering unit side | IP43 | |
| Degree of protection on CT/VT plug side | IP53 | |
| CT/VT plug material | Self-extinguishing synthetic resin class V0 (UL 94 standard) | |
| Flexible conduit | Compliant with CEI EN 61386-1 and CEI EN 61386-23 | |
| Intended use | Connection of GME MV DMI02004 to CT DMI031014 and VT DMI031015 in MV delivery compartments | |
| Installation | Indoor | |
| Product category | Connection cords for MV metering units |
DMI 02004.
European leaders in the design, manufacture and marketing of innovative systems for infrastructure, automotive, railways, energy and telecommunications.
Registered office
Via B. Zenale 40/A, 20024 Garbagnate Milanese (MI)
Operational office
Via Mongibello 97 - Zona Ind.le Piano Tavola, 95032 Belpasso (CT)